Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 228 of 228

Use Text with (Fx) functionality

When filling a textcode using the funtionality of f(x) you can choose a lot of data used or filled in the component you've add in your model. But when you copied the component a view times in the model, you want to use the functionality of the tex...
about 1 year ago in OpenBuildings Designer / Buildings Systems 0 Needs review

Opening placement - Sense Distance = 0

As discussed in this forum post https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/243581/obd-u10-wall-opening-cuts-compound-slab It is currently not possible to create an opening with "Sense dis...
over 2 years ago in OpenBuildings Designer / Architectural 4 Future consideration

Piping connection: Add option for 2x 135deg elbow

In sewer installations 90deg elbows are avoided. Instead we use 2x 135deg. It would be nice to have such an option in the "Connect" interface. Also maybe in the "Plumbing Autofitting Preferences". It might look like a small detail, certainly in th...
over 2 years ago in OpenBuildings Designer / Buildings Systems 6 Future consideration

Space - room bounding

We need a Space option that will allow the Space to follow the geometry it is associated too. thus if the space aka walls move the Space updates to suit. Revit offers this, and it is a limitation for OBD users
over 2 years ago in OpenBuildings Designer / Architectural 3 Already exists

Program Manager Notification

If we delete files from the Design folder (our workset) and these files were used in Program Manager for Design Options, we should have notification when we start OBD that there are no these files and existing Design Option was changed.
over 2 years ago in OpenBuildings Designer / Architectural 1 Future consideration

Penetrations: Apply Changes / Update Model - Object by Object

The current global 'all or nothing' updates are only useful 5% of the time. For the bulk of the updates a step by step update is required. No engineering team is going to be happy relying on the vendor's algo without the assurance of visual inspec...
over 2 years ago in OpenBuildings Designer / General 1 Future consideration

Penetrations: Bulk Edit in Excel and Synch back to OBD

Penetrations are quite complicated and not easily defined by a few rules. The current selection of rules I think will be quickly overwhelmed. As such, I can see most people decoupling the Penetration objects from the PM as soon as possible, then e...
over 2 years ago in OpenBuildings Designer / General 1 Future consideration

Structural Tool Open to Last Library Instead of Reset

Each time you go to place a structural member the tool resets to the base directory of the libraries. It would save a LOT of time is the tool remembered the last library list used and defaulted there instead of resetting to the beginning. It can b...
over 1 year ago in OpenBuildings Designer / Structural 0 Already exists

Clash detection report automation

See this thread https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/234812/report-on-clash/738991#738991 The way we use it now is in a teams session with all consultants. I share my screen and run...
over 2 years ago in OpenBuildings Designer / Architectural 2 Will not implement

Add cached files and live nesting function

For example, if we have 5(five) volume files referenced into a masterfile and this masterfile is referenced to a mastermodel where you take sections for 2D drawings. The 2D drawing is cached. When opening this file with live nesting set to 2, the ...
over 1 year ago in OpenBuildings Designer / General 1 Needs review