A new command for "Springpipe" (Stub that must have a negative value)

There is a new mechanical process to make a stub in a pipe for a sprinklerhead. They melt a hole in the pipe with a mechanical object and make a thread in the hole with the dimensions of the sprinklerhead. And the sprinklerhead can be screwed in t...
over 2 years ago in OpenBuildings Designer / Buildings Systems 4 Future consideration

ES: Print constructions/fabric build-ups and data under Data Managers>Materials

Energy Simulator. The print option was available in the old Hevacomp. Open Building use similar UI so why remove the print option in the first place? The print would provide a comprehensive details of the u-value, g-value, condensation check, k-va...
over 1 year ago in OpenBuildings Designer / Buildings Services 0 Needs review

filter out geometry from rounded steel profiles

A correct steel beam with rounded corners is ofcourse looking better in a shaded view. But it is problematic in drawings front view as it will produce a lot of lines. Try an ifc from Revit or Tekla and you will see. Best would be if OBD could filt...
over 2 years ago in OpenBuildings Designer / Architectural 1 Already exists

Named Group xsd for DataGroup System

It would be great to provide a way to assign a Named Group to any placed Objects and Assemblies, including the OOTB objects like Walls, Slabs etc. This will allow the user to manipulate multiple elements efficiently without having to nest within a...
over 2 years ago in OpenBuildings Designer / Architectural 1 Will not implement

Penetration manager/configuration

Individual openings should be deletable after utilizing the penetration manager tool. Individual openings should be manually adjustable in size after using the penetration manager tool.
over 1 year ago in OpenBuildings Designer / General 1 Future consideration

Export OBD Structural to Dlubal RFEM 6

For our structural analysis we are currently using the new RFEM 6 from Dlubal-Software and for the design part we are using Openbuildings Designer.In our BIM oriented projects we exchange our data between RFEM 6 and Openbuildings Designer mostly b...
almost 3 years ago in OpenBuildings Designer / Structural 0 Needs review

Implement bi direction links between the Datagroup System and External Databases

Make it simpler to connect to external databases, e.g. Building Smart data dictionary, SAP, user database, etc. The existing UDL technology has largely been underused and underdeveloped. Replacing it with something more robust and suitable for mod...
over 5 years ago in OpenBuildings Designer 2 Will not implement

Vertical Louvres

I have been working with Steve Cocchi to create a vertical Louvre. This new louvre will adjust the number of blades and allow you to to rotate them. It would be great to include these bespoke families & parts to the datasets for all to be able...
over 1 year ago in OpenBuildings Designer / Architectural 1 Will not implement

Merge Dataset family & parts

Within the different datasets, there are family and parts that do not exist in other datasets ie within the US dataset there are handrails with a glass panels, but in the UK dataset this is missing. There are many many other items that I feel shou...
over 1 year ago in OpenBuildings Designer / Architectural 1 Planned

Opening placement - Sense Distance = 0

As discussed in this forum post https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/243581/obd-u10-wall-opening-cuts-compound-slab It is currently not possible to create an opening with "Sense dis...
almost 3 years ago in OpenBuildings Designer / Architectural 4 Future consideration