Curtain wall profile

Curtain Wall profile: Curtain Wall profiles are not parametrically editable. Hence, raising an enhancement request to allow changes to the curtain wall profile using direct parameters, with more standard sizes to be added to the library/catalogue,...
3 months ago in OpenBuildings Designer / Architectural 2 Will not implement

Staircase - Label Co-ordinates

Label Co-ordinates not working on the staircase Hence raising an enhancement request to address this missing detail in OBD
3 months ago in OpenBuildings Designer / Architectural 1 Future consideration

Set Active Grids per selected building

current 'set active grids' function select all buildings defined in floor manager as default. It will be good to turn on only selected building in Floor Selector as default.
8 days ago in OpenBuildings Designer / General 0 Needs review

Angular Grids

Angular Grids do not display in the sections. Currently, grids that are angled and not perpendicular to the slice do not show up in Sections or Elevations. This results in missing angular grids on the drawing sheets. Additionally, when elevations ...
3 months ago in OpenBuildings Designer / Architectural 1 Future consideration

RFA in a Cell but not in the schedule

I must a lot of fire dampfer in a building and it is a RFA file of Solid Air. It is all the same room, So I create a cell to copy this in other rooms. But when I want to create a schedule, This is not listed in the schedule. It can also be done by...
6 days ago in OpenBuildings Designer / Buildings Systems 1 Needs review

Duplicated IFC properties when modifying default property value

When a default value is used in dg in the workspace and later you locally modify it in the file, Openbuilding shows the locally modified. (Expected) The issue is when you export to ifc, then both the default and the locally modify value are export...
2 months ago in OpenBuildings Designer / General 5 Needs review

Level Of Graphical Detail - LOgD

When working thought the various phases of a project, we have to develop a series of BIM objects based on the Level of Graphic Detail (LOgD) per design stage As a guide .. Concept design (CD) (stage 2 would typically be LOgD 200 Scheme Design (SD)...
23 days ago in OpenBuildings Designer / Architectural 0 Needs review

Replace Dynamic View tool ... too slow, painful and lacks accuracy

HI Support Please can I make a request on behalf of every one. We need a replacement tool for the Dynamic View tool. It is slow, painful to setup, inaccurate, unstable, clunky. We need a tool that is super fast, accurate, and allows editing of the...
30 days ago in OpenBuildings Designer / Architectural 0 Needs review

In the floor manager, it should be possible to create multiple sites (ifcSite) and then select them. German: Im Geschossebenenmanager sollte es möglich sein mehrere Standorte (ifcSite) erstellen und danach auswählen zu können

In the floor manager, it should be possible to create multiple sites (ifcSite) and then select them. Currently, only one project (ifcProject) and one site (ifcSite) can be set per workset. Only multiple buildings (ifcBuilding) can be added. It is ...
5 months ago in OpenBuildings Designer / General 4 Needs review

Elements created in particular floor level are not pinned with that level

Elements/Beams modelled in a particular floor level are not pinned with that level and need to move manually if there is any change in level through level manager
2 months ago in OpenBuildings Designer / Structural 1 Future consideration