Elements created in particular floor level are not pinned with that level

Elements/Beams modelled in a particular floor level are not pinned with that level and need to move manually if there is any change in level through level manager
7 months ago in OpenBuildings Designer / Structural 1 Future consideration

Allow Updates to Cached Drawings with missing references

If a reference is removed from a composition model, then any cached drawings referencing Saved Views from that composition model will get an error message that prevents the cached DV from updating. There are several reasons that users may want to ...
almost 3 years ago in OpenBuildings Designer / General 4 Future consideration

Associate structural elements to grid lines

Structural elements are associated to grids so changes to grid layout will propagate to associated elements, such as beams, columns, bearing walls, and footings.
about 4 years ago in OpenBuildings Designer / Structural 0 Future consideration

Parametric Frame/Cell Builder

There is currently no effective means to generate and update Parametric / Compound Cells. Including the proxy view dependent geometry is key to reducing BV,DV generation times. Also needed to automate and coordinate detail drawing production. The ...
about 1 year ago in OpenBuildings Designer / General 1 Future consideration

Allow GC to work with Curtain wall tool

I would like to be able to use GC and drive a curtain wall. This would allow us to use GC to fit the CW to bespoke elements etc. Buildings are becoming more and more curved, GC would aid the design Ian
3 months ago in OpenBuildings Designer / Architectural 0 Future consideration

Level Of Graphical Detail - LOgD

When working thought the various phases of a project, we have to develop a series of BIM objects based on the Level of Graphic Detail (LOgD) per design stage As a guide .. Concept design (CD) (stage 2 would typically be LOgD 200 Scheme Design (SD)...
6 months ago in OpenBuildings Designer / Architectural 0 Future consideration

Creating native Revit files

Native Revit file Here in Holland the Architect, contructions, mechanical and Electric firms demand to use Revit. In their BIM protocols they demand to collaborate with RVT and IFC files. They demand me to collaborate this way. I don't have any so...
almost 2 years ago in OpenBuildings Designer / General 5 Needs review

Text alignment isn't working when we use the leader feature in OBD software.

For Example, for notes, adjusting the left and right alignment is not straightforward. While these settings can be changed globally, they cannot be modified for individual notes. However, this adjustment is possible for text elements. Therefore, w...
6 months ago in OpenBuildings Designer / General 1 Future consideration

Spot level, tag, and callout are not updating automatically; we have to update them manually each time.

Spot level, tag, and callout are not updating automatically; we have to update them manually each time.
6 months ago in OpenBuildings Designer / General 1 Needs review

Prostructures Ribbon

So, in OBD, you can activate a Prostructures license You are then able to place all the Prostructures items, but you need to know the key-in to get to all the Prostructures placements, It would be good if there were a way to get the Prostructures ...
9 months ago in OpenBuildings Designer / Structural 2 Future consideration