Rhino inside

HI Bentley I was just looking at Revit/Rhino/Grasshopper and they are all linked via a tool called Rhino Inside. https://www.rhino3d.com/inside/revit/1.0/ When revit, rhino and grasshopper are linked, the tool sets are added to each of the 3 appli...
about 1 month ago in OpenBuildings Designer / Architectural 0 Needs review

English translation: Please add a design for fixing points in the pipe support. The fixed support of the pipe system (i.e., all three-way displacements must be constrained to 0) requires a combination of a guide and a limit support. Two hangers will be generated when generating the hanger. Original text: 请在pipe的支架中增加固定点的设计。管系的固定支架(即三向位移都要被约束为0)需要用一个导向加一个限位支架组合,生成支吊架的时候会出现两个支吊架.

请在pipe的支架中增加固定点的设计。管系的固定支架(即三向位移都要被约束为0)需要用一个导向加一个限位支架组合,生成支吊架的时候会出现两个支吊架。请增加一个固定支架选项English translation: Please add a design for fixing points in the pipe support. The fixed support for the pipe system (i.e. all three-way displacements are constr...
4 months ago in OpenBuildings Designer / Buildings Systems 1 Needs review

Creating native Revit files

Native Revit file Here in Holland the Architect, contructions, mechanical and Electric firms demand to use Revit. In their BIM protocols they demand to collaborate with RVT and IFC files. They demand me to collaborate this way. I don't have any so...
about 1 year ago in OpenBuildings Designer / General 5 Needs review

Filled spaces are not displayed with display rules

A behavior that should be corrected. By indicating filled spaces in dynamic view, the spaces are not shown filled. If we indicate display rules for these spaces in dynamic views, the spaces are shown as indicated by the display rules but are no...
8 months ago in OpenBuildings Designer / Architectural 0 Needs review

Use of the Exchange Reference Command

When we have file A active and B and C referenced, selecting B and using Exchange is simply equivalent to opening file B. The ideal function would be to open file B with A and C referenced.
8 months ago in OpenBuildings Designer / Architectural 1 Needs review

ES: Print constructions/fabric build-ups and data under Data Managers>Materials

Energy Simulator. The print option was available in the old Hevacomp. Open Building use similar UI so why remove the print option in the first place? The print would provide a comprehensive details of the u-value, g-value, condensation check, k-va...
4 months ago in OpenBuildings Designer / Buildings Services 0 Needs review

Individuell erzeugte Bauteile mit dem Zeichnungsfilter bearbeiten

Individuell erzeugte Bauteile mit dem Zeichnungsfilter bearbeiten. Individuell erzeugte Bauteile werden für den Unternehmensstandard benötigt. Die nachträgliche Anpassung im Zeichnungsfilter ist erforderlich und erleichtert die tägliche Arbeit er...
5 months ago in OpenBuildings Speedikon 0 Needs review

2D section export from Imodels

When cutting a section in an Imodel within the Design review environment it would be good if a user could export that 2D section as a DGN file?
over 2 years ago in OpenBuildings Designer / Digital Twins 3 Needs review

Color 255

Nowadays there are lot of BIM technique with different CAD software. If I read an IFC in OBD other CAD software use color 255 in the Part and family. So when I want to plot or create a pdf file, this color doesn't show up on paper or pdf. Because ...
7 months ago in OpenBuildings Designer / General 1 Needs review

Design Options - More than just spaces

Bentley. Can you expand the options of using design options to more than just Spaces. I feel this would be a great tool for the entire project. Ian
7 months ago in OpenBuildings Designer / Architectural 1 Needs review