Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 79

Allow batch mode without GUI

As per the manual (OpenBuildings Speedikon CONNECT Edition Update 4.2) , the export of IFC files can be batch processed by creating a job.lst file in PROJECT\des\bat\COMPUTERNAME\ife\job.ptk and then running speedm.exe "-mod" "design" "-prj" "proj...
9 months ago in OpenBuildings Speedikon 1 Needs review

Room Ref and Room name lines when creating a new room

When tracing a new room, the window pops up to input the room reference. I want an additional line put in, so i can write the room name/description, as well as the room reference. Currently, i have to compelte tracing the room to create the room, ...
about 2 months ago in OpenBuildings Designer / Buildings Services 0 Needs review

Room by Room Schedule Summary

I want a facility to quickly print a schedule that shows every room within the whole building and sumamrises the area of each room and the occupancy of that room. I do not want a total for the whole building. It needs to be on a room by room basis...
about 2 months ago in OpenBuildings Designer / Buildings Services 0 Needs review

Creating native Revit files

Native Revit file Here in Holland the Architect, contructions, mechanical and Electric firms demand to use Revit. In their BIM protocols they demand to collaborate with RVT and IFC files. They demand me to collaborate this way. I don't have any so...
over 1 year ago in OpenBuildings Designer / General 5 Needs review

Sprinklerhead rfa import

When I import the rfa file of a sprinklerhead, I can't choose the datagroup of a sprinkler system. Because Sprinkler is a different disciplin in Mechanical world. It is a safety. And OBD have a menu for Sprinkler called "Fire protection", but if i...
3 months ago in OpenBuildings Designer / Buildings Systems 0 Needs review

Model Audit tool

We have a series of very large infrastructure projects ie Rail station, airport , football stadium etc. typically these project contain several hundred DGN files and many more 2d files. In terms of 3d DGN files, one thing we are lacking is an AUDI...
3 months ago in OpenBuildings Designer / Architectural 0 Needs review

Create datagroup for elbows wih male-male/male-female connections

There are a lot of elbows and tees with wire connections. And when modifying excisting datagroup, OBD have a limitation to create these fittings. And Revit can do all fittings and also with the right image and dimensions. When will OBD do this, be...
3 months ago in OpenBuildings Designer / Buildings Systems 0 Needs review

Material alignment

If you have a building that contain a series of walls, if the building is rotated away from the horizontal and apply materials via the family and parts. when the building is cut the materials are never aligned with building ie a wall (see image) I...
3 months ago in OpenBuildings Designer / Architectural 0 Needs review

Data of RFA files

Data of RFA files, OBD doesn't read correctly to create schedules automaticly
3 months ago in OpenBuildings Designer / Buildings Systems 0 Needs review

English translation: Please add a design for fixing points in the pipe support. The fixed support of the pipe system (i.e., all three-way displacements must be constrained to 0) requires a combination of a guide and a limit support. Two hangers will be generated when generating the hanger. Original text: 请在pipe的支架中增加固定点的设计。管系的固定支架(即三向位移都要被约束为0)需要用一个导向加一个限位支架组合,生成支吊架的时候会出现两个支吊架.

请在pipe的支架中增加固定点的设计。管系的固定支架(即三向位移都要被约束为0)需要用一个导向加一个限位支架组合,生成支吊架的时候会出现两个支吊架。请增加一个固定支架选项English translation: Please add a design for fixing points in the pipe support. The fixed support for the pipe system (i.e. all three-way displacements are constr...
7 months ago in OpenBuildings Designer / Buildings Systems 1 Needs review