Individual openings should be deletable after utilizing the penetration manager tool. Individual openings should be manually adjustable in size after using the penetration manager tool.
Improvement in Family/Parts Editor and Catalog Editor
Hi,
It will be appreciate to have a better respect of the general Windows convention in these two dialog boxes.
1) They are similar but they are working differently
2) When an entity is editable in the tree or in the listview (right side), F...
As there is an increase awareness on carbon emission and a need to calculate the embedded carbon rate per volume of material assigned in the model, it should be time for this parameter to be included and rate set based on standard EC rate. Current...
Very old request! Pretty much every other BIM app handles this without any fuss. Not sure why Bentley seems to struggle with this. We need to be able to extract and report height elevation info based on a user defined coordinate system (usually th...
Support for overrides would be a big productivity booster. Overlaps with Ideas / worflows for: 1. Penetration Object level rules / configs. Progressive refinement of low LOD rules into higher LOD rules via a 'parent - children' sub-classing workfl...
Penetrations: Managment of follow on associations / call backs.
The PM apparently records the call backs triggered by Mstn's tools that manipulate / modify the cutting / cut elements for each Penetration object. When the user triggers an Update, the PM dialog is updated and the PO is updated in the model. It w...
Link access databases to datagroup other than mechanical
It would work the same way it already does for mechanical datagroup instances. To have the ability to link an Access database to datagroups from other specialties. It would be helpful if you have codes for specs or BOQs, organized in a database. O...
Add constraint to elements (such as walls) to have their height or placement location to be defined relative to floor above, floor below, or other plane defined in Floor Manager. This would cause elements to change their element height and/or moun...
Floor Manager and Grid tools should recognise Coordinate Systems and enable defined building locations
On large projects, with multiple (& repeated) buildings it is common to model the building around the file origin, and then reference/place into actual location. The current system does not recognise if the refernce is moved, so the floor mana...
Similar as in the Grid manager we need the option for the floor manager to "Rotate by points" so that a building can be positioned and rotated properly.