General

Showing 80 of 201

Definition editor string property limited to 255

When a property is defined as string in definition editor despite there are fields where you can declare the maximum and minimun length, the program trunks the string at 255 characters instead the number you define as maximum length
almost 2 years ago in OpenBuildings Designer / General 3 Future consideration

Option to ungroup components placed as array parametric solid

Filing this idea on behalf of B+S AG | Stefan Schöni. While using the command "Array parametric solid feature", the components are 'grouped' - this is still the case in the IFC file. This means that no evaluations can be made because, for example,...
5 months ago in OpenBuildings Designer / General 1 Future consideration

Allow non-parametric cells to be placed as shared cells through the DG placement dialogs.

Users would like an option to place cells through the DataGroup enriched placement dialogs (as opposed to Compound Cell Manager or Cells dialog) as Shared Cells. Users have several detailed cells that are used many times in the same model. Without...
almost 2 years ago in OpenBuildings Designer / General 2 Future consideration

Dataset.cfg variable MS_DGNLIBLIST_LINESTYLES need to be set to '<'

OBD 2023 using the ISO19650 dataset, the Dataset.cfg has the variable MS_DGNLIBLIST_LINESTYLES = $(TFDIR)Dgnlib\Linestyles,dgnlib With it set the equals, it will not read any similar MS_DGNLIBLIST_LINESTYLES variables that has been set to either a...
6 months ago in OpenBuildings Designer / General 1 Planned

Annotation Tools Refresh

Some of OBD's Annotation tools date back to the 90s and need to be updated. A lot of OBD's functionality is also based on new Mstn tech like DV callouts (Place Section Callout, Place Detail Callout, Place Elevation Callout, Place Plan Callout, Pla...
over 2 years ago in OpenBuildings Designer / General 1 Planned

Sort Saved Views (Orientation) in Attach Reference

When you attach a reference and open the Orientation, you can choose a Saved View within the file. The list shows the SVs in order of creation. It would be nice to be able to sort them (by View or Description).
about 1 year ago in OpenBuildings Designer / General 1 Future consideration

Use of Configuration explorer for OBD2023

For me It is easy to use Configuration Explorer to split the Delivered datasets WorkSpace an WorkSet. It will be very helpfull when support update the Configuration Explorer for OBD2023 because it is very clear. And when in Bentley learn the BIM30...
about 1 year ago in OpenBuildings Designer / General 2 Future consideration

Concatenate 2 dg properties

I would like to concatinate 2 dg properties into 1 property. Ex. DoorID = SpaceNumber+DoorNumber.
over 1 year ago in OpenBuildings Designer / General 3 Will not implement

Upgrade design file cleanup tool to work with building elements

in basic MS the design file cleanup tool is very useful at removing duplicate elements, this should be upgraded to work with Building elements such as walls, doors, windows(and all objects) and structural elements also.
over 2 years ago in OpenBuildings Designer / General 1 Future consideration

Penetration manager/configuration

Individual openings should be deletable after utilizing the penetration manager tool. Individual openings should be manually adjustable in size after using the penetration manager tool.
4 months ago in OpenBuildings Designer / General 1 Future consideration