room are not in alphabetical order

Room appears in the project tree in order of tracing it not in alphabetical order. The trouble is it cannot be changed and it is being replicated in all the results and reports. Numbers are often a part of room names, so I often end up with room n...
26 days ago in OpenBuildings Designer / Buildings Services 0 Needs review

Open RVT files directly

It would be great to be able to open RVT files without having to use iTwins. Increasingly using BricsCAD BIM to open up RVT files to look at what is inside. Works great! A lot of manufacturers are providing their content as RVT files, instead of s...
3 months ago in OpenBuildings Designer / General 1 Future consideration

Parametric Frame/Cell Builder

There is currently no effective means to generate and update Parametric / Compound Cells. Including the proxy view dependent geometry is key to reducing BV,DV generation times. Also needed to automate and coordinate detail drawing production. The ...
3 months ago in OpenBuildings Designer / General 1 Future consideration

IFC entity mapping for subcomponents of Curtain Wall

The subcomponents Panels and Mullions of Curtain Wall now mapped to IfcBuildingElementProxy in IfcEntity when exported to IFC4 in OpenBuildings. Tried to modify the mapping options in the IFC Export dialog or edit the IFC_PartMapping_ifc4.set to a...
2 months ago in OpenBuildings Designer / General 1 Future consideration

Being able to input a ceiling plenum after an exposed ceiling design change

Currently there is no way to change from an exposed ceiling design to now a ceiling plenum without starting again once created. Designs change so this should be an easy change also
about 1 month ago in OpenBuildings Designer / General 0 Needs review

Railing with baseboard

The problem is that it is not possible to use a flat iron profile from the standard catalog because this profile is always placed horizontally instead of vertically on the railing. I have not found a way to place the profile rotated by 90 degrees....
about 1 year ago in OpenBuildings Designer / Buildings Systems 1 Needs review

Allow batch mode without GUI

As per the manual (OpenBuildings Speedikon CONNECT Edition Update 4.2) , the export of IFC files can be batch processed by creating a job.lst file in PROJECT\des\bat\COMPUTERNAME\ife\job.ptk and then running speedm.exe "-mod" "design" "-prj" "proj...
7 months ago in OpenBuildings Speedikon 1 Needs review

OBD Selects references

I want to lock references to prevent them from being selected.
about 2 months ago in OpenBuildings Designer / Architectural 2 Needs review

Creating native Revit files

Native Revit file Here in Holland the Architect, contructions, mechanical and Electric firms demand to use Revit. In their BIM protocols they demand to collaborate with RVT and IFC files. They demand me to collaborate this way. I don't have any so...
about 1 year ago in OpenBuildings Designer / General 5 Needs review

Rhino inside

HI Bentley I was just looking at Revit/Rhino/Grasshopper and they are all linked via a tool called Rhino Inside. https://www.rhino3d.com/inside/revit/1.0/ When revit, rhino and grasshopper are linked, the tool sets are added to each of the 3 appli...