Unify different parts in each drawing

It would be a good idea if in a drawing you could override part join configurations and create a new configuration for that drawing. For example, join all the walls, pillars, partitions, etc. in a floor plan or only join the walls of the same mate...
9 months ago in OpenBuildings Designer / Architectural 1 Future consideration

Family and part tab in PCS

In Parametric Cell Studio OBD CE 2023, the tab to indicate Family and part is not shown. The attribute must be indicated manually. More time and more mistakes. Requested: Adding the family and part tab for PCS components See explanatory image.
9 months ago in OpenBuildings Designer / Architectural 3 Will not implement

Modify PAZ with Parametric Cell Studio

When a PAZ cell is modified with PCS, the modified copy appears at point 0,0,0. The previous copy remains. It is requested: change this behavior and replace the modified cell in its place of placement, as it worked in OBD V8i See attached video
9 months ago in OpenBuildings Designer / Architectural 0 Needs review

Reconstruct hidden wall joints

Problem: Two walls with different parts that unify each other (section and F/R view). A wall must be demolished. The other wall must be maintained. If we visualize the two walls, we see the current state. The two walls are shown joined. This is...
9 months ago in OpenBuildings Designer / Architectural 1 Future consideration

Allow option to remove Context Menu items that are not loaded in from the GUI.dgnlib

The right click context menus have items that are loaded into it from outside a dgn library, provide method to show /hide all context menu items, not just the ones designated thorough a dgn.lib file.
over 1 year ago in OpenBuildings Designer / General 0 Needs review

Automatic DataGroup upgrade after schema changes

When DG schema is changed some tools (incl. Edit Properties, IFC Export) do no work proper until user manually run DG Upgrade tool.Same time user has no indication he needs to upgrade. It may happen when user opens old dgn with newer OBD version o...
over 4 years ago in OpenBuildings Designer 0 Future consideration

Overall simplification of the steps required to link a database to a datagroup catalog such as piping systems

The process to create a link between an Access database and some datagroup info is painfull at least. Manually editing xml files, making sure everything matches between properties, database columns names, units, making sure we are not using some t...
over 1 year ago in OpenBuildings Designer / Buildings Services 2 Future consideration

Link access databases to datagroup other than mechanical

It would work the same way it already does for mechanical datagroup instances. To have the ability to link an Access database to datagroups from other specialties. It would be helpful if you have codes for specs or BOQs, organized in a database. O...
over 1 year ago in OpenBuildings Designer / General 4 Future consideration

Penetrations: Overrides

Support for overrides would be a big productivity booster. Overlaps with Ideas / worflows for: 1. Penetration Object level rules / configs. Progressive refinement of low LOD rules into higher LOD rules via a 'parent - children' sub-classing workfl...
over 2 years ago in OpenBuildings Designer / General 1 Future consideration

Penetrations: Managment of follow on associations / call backs.

The PM apparently records the call backs triggered by Mstn's tools that manipulate / modify the cutting / cut elements for each Penetration object. When the user triggers an Update, the PM dialog is updated and the PO is updated in the model. It w...
over 2 years ago in OpenBuildings Designer / General 1 Future consideration