Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 206 of 206

grid balloon text

When you create a GRID system and define the Grid balloons, if the grid is not orthogonal to the view ie a building is not horizontal, when the grid is placed, the balloon text is placed at an odd angle. These text are unable to be rotated to the ...
almost 2 years ago in OpenBuildings Designer / Architectural 1 Future consideration

Parametric cell and repeated drawing symbols

In Parametric Cell Studio, lines, rectangles, etc. could be repeated a number of times according to a variable to represent the top view drawing, for example. In parametric cells, this is not possible. It is possible to use a parametric solid arra...
8 months ago in OpenBuildings Designer / Architectural 1 Future consideration

Symbols Compound cells

In OBD V8i there was the possibility of referencing a cell as a drawing symbol in BXC. It could then be embedded and saved as a drawing symbol.In OBD 2023 the behavior has changed and they appear in red and the cell cannot be embedded as a drawing...
8 months ago in OpenBuildings Designer / Architectural 5 Needs review

Parametric cells need to place handles

In Parametric Cell Studio, there is the possibility of placing handles to change the dimension of a measurement. The change updates the dimensions of the entire cell.It would be interesting to be able to use this option in Parametric Cell and not ...
8 months ago in OpenBuildings Designer / Architectural 2 Future consideration

Resolve slab encounter with stair

Staircase encounters with the slab are not considered in OBD. It would be interesting to be able to adjust them directly in the stair settings so that they are similar to reality when they are built.See image
8 months ago in OpenBuildings Designer / Architectural 1 Future consideration

Parametric Cell does not display drawing symbols correctly

When placing a parametric cell, the preview of the top view symbols is displayed correctly if they are activated in the Building settings. If they are not activated in the Building settings but Named Presentation is activated, the top view and the...
8 months ago in OpenBuildings Designer / Architectural 1 Future consideration

Improve parametric cells for doors and windows

The behavior of parametric cells must be improved in order to replace PCS and BXC to create doors and windows.When modifying a parametric door, strange behavior is observed. If the width is enlarged with the handle, the door is not modified in the...
8 months ago in OpenBuildings Designer / Architectural 2 Future consideration

Create Full Wall in Model that is the Full Wall Section - LOD

The current wall is fine as is but NOT complete. Works ok for interior walls but ignores what the true section looks like in section, No Blocking, Flashing etc. Honestly it is A+ for floor plans, it is the section that is pour. Plans never need th...
over 1 year ago in OpenBuildings Designer / Architectural 2 Future consideration

Create space by flood on Referenced geometry

Currently the "Create space - Flood Area" only works on geometry in the active model. I'd be nice to also be able to use it with referenced geometry. See also Idea 138 - Create wall from space in Referenced File. Making this possible would probabl...
over 2 years ago in OpenBuildings Designer / Architectural 5 Already exists

Improvement in Family/Parts Editor and Catalog Editor

Hi, It will be appreciate to have a better respect of the general Windows convention in these two dialog boxes. 1) They are similar but they are working differently 2) When an entity is editable in the tree or in the listview (right side), F...
over 2 years ago in OpenBuildings Designer / General 2 Future consideration