My votes: Architectural

Showing 83 of 242

Curtain Wall : ACS & Accudraw Compliance

The CW tool ignores the ACS, Accudraw orientation when the CW is placed (ACS Plan Lock on etc). This is not expected behaviour, and severely limits the usability of the tool. The CW object can be rotated to match the ACS after being placed. Being ...
over 1 year ago in OpenBuildings Designer / Architectural 1 Needs review

Enable Program Area of a space to constrain its size

Enable Program Area of a space to constrain its size (rubber-banding capability) so user can adjust a side and have the shape respond. 2D constraints in MicroStation can do this, see video (the video is real-time; scrub through to get the picture ...
about 5 years ago in OpenBuildings Designer / Architectural 3 Future consideration

Local CS for Curtain Walls

The CW tool is pretty powerful, but it works only in the vertical plane as a 'wall'. The panelisation that the CW tool is useful as a lot of construction objects are based on panels and grids. Eg Cladding panels and frames, tiles and joints, celin...
over 1 year ago in OpenBuildings Designer / Architectural 2 Needs review

Staircase volume in quantity property tab

Want to see the concrete volume for staircase in quantity properties tab.
almost 2 years ago in OpenBuildings Designer / Architectural 6 Future consideration

Convert an associative flooded space to a non-associative space

It would be good if a user could initially place spaces using the flood placement option as this is a quick and efficient way to add spaces and room data to a model in the early stages of design. Later in the process, he may need to be more exact ...
over 3 years ago in OpenBuildings Designer / Architectural 0 Planned

Allow unfiers between parts

There is a need for unifiers work between parts
over 3 years ago in OpenBuildings Designer / Architectural 1 Needs review

Create part - add DGN,CEL to the list of available files

When you create a 3d part, this would typically be a DGN or a cell. Although it is possible to edit the xsd files to include DGN and cel as a format, this is not set by default. Now that we have parametric modelling the DGN format needs to be visi...
over 2 years ago in OpenBuildings Designer / Architectural 1 Needs review

ad Area Tools from v8i

ad Area Tools from v8i
over 2 years ago in OpenBuildings Designer / Architectural 2 Needs review

Set default wall connect type

Currently when drawing new walls, the default connection is mitred (called 'bi-sector' in the "Connect Forms" tool). This is very unconventional, so I'd rather set the default to 'Parallel'. Now I have to re-do all connections after drawing the wall.
over 2 years ago in OpenBuildings Designer / Architectural 0 Needs review

Multi-selection and drag-drop option for Spaces in Program Manager

When we import the data from Excel to Program Manager all spaces are added as long list and to realize where they should be placed we have to group them. Right now we can just Cut and Paste one by one each Space to move them from the common list t...
over 2 years ago in OpenBuildings Designer / Architectural 0 Needs review