Removing or reassigning instance data does not work after placing OBD elements. German: Instanzdaten entfernen bzw. neu zuordnen funktioniert nach dem Platzieren von OBD-Elementen nicht

Removing or reassigning instance data no longer works after placing OBD elements (walls, railings, steel beams, profiles, etc.). German: Instanzdaten entfernen bzw. neu zuordnen funktioniert nach dem Platzieren von OBD-Elementen (Wänden, Geländer,...
7 months ago in OpenBuildings Designer / General 2 Needs review

Double Angles and Channels as 2 Single Angles

The Combined shape option is too time consuming to create for this content. It also does not transfer to other applications (ProStructures, TEKLA, Etc.). These applications want to display them as two separate angles. The spacing is dictated by th...
7 months ago in OpenBuildings Designer / Structural 2 Already exists

Open RVT files directly

It would be great to be able to open RVT files without having to use iTwins. Increasingly using BricsCAD BIM to open up RVT files to look at what is inside. Works great! A lot of manufacturers are providing their content as RVT files, instead of s...
10 months ago in OpenBuildings Designer / General 2 Future consideration

Need sloped slab from compound slab option

Team needs it and creating sloped slab now is a challenge.
about 1 year ago in OpenBuildings Designer / Architectural 4 Future consideration

fundamental element properties within the Schedules

The DataGroup System does not provide a direct, user-configurable method to report on fundamental MicroStation element properties (e.g., raw XYZ coordinates from Range Low/High, or the element's source file name) within the Schedules tool for all ...
about 2 months ago in OpenBuildings Designer / Architectural 0 Future consideration

Association of the Mark in the structural Data with the member section

Association of the 'Mark' in the structural Data section with the section size, so that it changes automatically when member modified to another section. In addition, the changes should reflect automatically in the associated annotation with reloa...
5 months ago in OpenBuildings Designer / Structural 1 Needs review

Elements created in particular floor level are not pinned with that level

Elements/Beams modelled in a particular floor level are not pinned with that level and need to move manually if there is any change in level through level manager
5 months ago in OpenBuildings Designer / Structural 1 Future consideration

Level Of Graphical Detail - LOgD

When working thought the various phases of a project, we have to develop a series of BIM objects based on the Level of Graphic Detail (LOgD) per design stage As a guide .. Concept design (CD) (stage 2 would typically be LOgD 200 Scheme Design (SD)...
3 months ago in OpenBuildings Designer / Architectural 0 Future consideration

Definition editor string property limited to 255

When a property is defined as string in definition editor despite there are fields where you can declare the maximum and minimun length, the program trunks the string at 255 characters instead the number you define as maximum length
over 2 years ago in OpenBuildings Designer / General 3 Future consideration

Elements need to be assigned correctly when in multiple spaces

When elements overlap multiple spaces (in some instances all they need to do is touch another space) the element is assigned to the first space placed. This is not always correct and results in incorrect scheduling. It is critical that elements ca...