Showing 133

fundamental element properties within the Schedules

The DataGroup System does not provide a direct, user-configurable method to report on fundamental MicroStation element properties (e.g., raw XYZ coordinates from Range Low/High, or the element's source file name) within the Schedules tool for all ...
about 2 months ago in OpenBuildings Designer / Architectural 0 Future consideration

Elements need to be assigned correctly when in multiple spaces

When elements overlap multiple spaces (in some instances all they need to do is touch another space) the element is assigned to the first space placed. This is not always correct and results in incorrect scheduling. It is critical that elements ca...
2 months ago in OpenBuildings Designer / General 1 Future consideration

Changing system property order

For customized properties, I can define display order, but can not define with system properties. Also it is difficult to redefine property set order. it will be good to have controls on them.
2 months ago in OpenBuildings Designer / General 0 Future consideration

Set Active Grids per selected building

current 'set active grids' function select all buildings defined in floor manager as default. It will be good to turn on only selected building in Floor Selector as default.
3 months ago in OpenBuildings Designer / General 0 Future consideration

Level Of Graphical Detail - LOgD

When working thought the various phases of a project, we have to develop a series of BIM objects based on the Level of Graphic Detail (LOgD) per design stage As a guide .. Concept design (CD) (stage 2 would typically be LOgD 200 Scheme Design (SD)...
3 months ago in OpenBuildings Designer / Architectural 0 Future consideration

Text alignment isn't working when we use the leader feature in OBD software.

For Example, for notes, adjusting the left and right alignment is not straightforward. While these settings can be changed globally, they cannot be modified for individual notes. However, this adjustment is possible for text elements. Therefore, w...
4 months ago in OpenBuildings Designer / General 1 Future consideration

Elements created in particular floor level are not pinned with that level

Elements/Beams modelled in a particular floor level are not pinned with that level and need to move manually if there is any change in level through level manager
5 months ago in OpenBuildings Designer / Structural 1 Future consideration

Staircase - Label Co-ordinates

Label Co-ordinates not working on the staircase Hence raising an enhancement request to address this missing detail in OBD
5 months ago in OpenBuildings Designer / Architectural 1 Future consideration

Angular Grids

Angular Grids do not display in the sections. Currently, grids that are angled and not perpendicular to the slice do not show up in Sections or Elevations. This results in missing angular grids on the drawing sheets. Additionally, when elevations ...
5 months ago in OpenBuildings Designer / Architectural 1 Future consideration

Creating new Catalog

I have copied an excisting mdb and xml file and modify all. But OBD can't design with it. Support send me here to upload this idea. Because I have design it with delivered catalog. But I have to change this, because this is not the right catalog. ...