My main work with the MEP modules in OBD is to create some sewer models. They are always with sloped pipes.
Currently it is very difficult to add or change the pipe slopes after placement. For example, I would like to first model everything without slope. Then select the entire system and apply the slope. This currently doesn't work.
Also changing the slope afterwards (for example started with 1% slope, have to change to 1,5%) is not working. Which means completely redrawing the entire pipe section.
How frequently will feature be used? | Once a week |
How much time will you save? | Lots! Attaching sloped pipe to things like drains is a nightmare currently. Half the time I even give up to have them attached. |