Sprinklerhead rfa import

When I import the rfa file of a sprinklerhead, I can't choose the datagroup of a sprinkler system. Because Sprinkler is a different disciplin in Mechanical world. It is a safety. And OBD have a menu for Sprinkler called "Fire protection", but if i...
3 months ago in OpenBuildings Designer / Buildings Systems 0 Needs review

Model Audit tool

We have a series of very large infrastructure projects ie Rail station, airport , football stadium etc. typically these project contain several hundred DGN files and many more 2d files. In terms of 3d DGN files, one thing we are lacking is an AUDI...
3 months ago in OpenBuildings Designer / Architectural 0 Needs review

Section callout

Section callout should be moved by the keyboard's arrows.
6 months ago in OpenBuildings Designer / General 4 Future consideration

Trim/Extend Multiple Walls

The Connect Walls command only works on 1 wall at a time. If the users need to extend multiple walls to touch another wall, the user must click the same wall multiple times. We should strive to match the workflow available in the Trim to Element C...
about 5 years ago in OpenBuildings Designer / Architectural 2 Future consideration

Create datagroup for elbows wih male-male/male-female connections

There are a lot of elbows and tees with wire connections. And when modifying excisting datagroup, OBD have a limitation to create these fittings. And Revit can do all fittings and also with the right image and dimensions. When will OBD do this, be...
3 months ago in OpenBuildings Designer / Buildings Systems 0 Needs review

Material alignment

If you have a building that contain a series of walls, if the building is rotated away from the horizontal and apply materials via the family and parts. when the building is cut the materials are never aligned with building ie a wall (see image) I...
3 months ago in OpenBuildings Designer / Architectural 0 Needs review

Data of RFA files

Data of RFA files, OBD doesn't read correctly to create schedules automaticly
3 months ago in OpenBuildings Designer / Buildings Systems 0 Needs review

Annotation Tools Refresh

Some of OBD's Annotation tools date back to the 90s and need to be updated. A lot of OBD's functionality is also based on new Mstn tech like DV callouts (Place Section Callout, Place Detail Callout, Place Elevation Callout, Place Plan Callout, Pla...
about 3 years ago in OpenBuildings Designer / General 1 Planned

room ref numbers on the layout cannot be relocated

Sometimes we do not have room references from architects and we need to create them ourselves. We need to be able to show clearly the location of particular room on the layout - it can be done in wireframe top view. Unfortunately sometimes room nu...
3 months ago in OpenBuildings Designer / Buildings Services 0 Needs review

English translation: Please add a design for fixing points in the pipe support. The fixed support of the pipe system (i.e., all three-way displacements must be constrained to 0) requires a combination of a guide and a limit support. Two hangers will be generated when generating the hanger. Original text: 请在pipe的支架中增加固定点的设计。管系的固定支架(即三向位移都要被约束为0)需要用一个导向加一个限位支架组合,生成支吊架的时候会出现两个支吊架.

请在pipe的支架中增加固定点的设计。管系的固定支架(即三向位移都要被约束为0)需要用一个导向加一个限位支架组合,生成支吊架的时候会出现两个支吊架。请增加一个固定支架选项English translation: Please add a design for fixing points in the pipe support. The fixed support for the pipe system (i.e. all three-way displacements are constr...