Provide 3 options to all cut elements in a view: No fill, solid fill (black or gray), or original fill, instead of the current system which only shows the cut fills defined in the Part/Family system
Rule system to reduce area/volume of rooms based on sloped elements above, such as roofs and stairs, niches and floor-to-ceiling windows, and columns, in space reports
Generate element ID numbers based on their floor number and space location. For examples, manually label a space "03" on the first floor, becomes "103". A door that is manually labeled "A", opening into room 104 becomes "104A"
Enable Program Area of a space to constrain its size
Enable Program Area of a space to constrain its size (rubber-banding capability) so user can adjust a side and have the shape respond. 2D constraints in MicroStation can do this, see video (the video is real-time; scrub through to get the picture ...
Take Schematic and or existing models data from OCP, and bring it into a design session inside OBD Create a workflow to display OBD data and geometry inside OCP
A heavily requested feature is to allow objects to be constrained by floor plane. If the floor level adjusts the geometry adjusts. Reference planes with object associations
(Speedikon GAP analysis)
Clean-up Walls(and other forms) Through References
In a federated model, if I have 2 walls in separate files, it can be very difficult to clean up walls that are interacting between different models. We need to allow the Connect Wall tool (specifically connect as L Parallel and Connect Forms as L ...
The Connect Walls command only works on 1 wall at a time. If the users need to extend multiple walls to touch another wall, the user must click the same wall multiple times. We should strive to match the workflow available in the Trim to Element C...